{"product_id":"components-example-product-1","title":"ACL-110 Digital Free Chlorine\/Chlorine Dioxide Sensor","description":"\u003cdiv class=\"product_desc not-italic font-normal no-underline\"\u003eThis ACL-110  free chlorine\/chlorine dioxide sensor uses advanced Swiss technology with silicon nitride-coated films and silicon semiconductors, plus built-in chlorine\/temperature probes. MEMS-based microelectronics are injection-molded for durability.\u003cbr\u003eIt detects free chlorine\/chlorine dioxide via varying currents (concentration-dependent), processed to standard Modbus RS485 signals.With features of 10 bar pressure resistance, flow\/pressure immunity, 9 months of maintenance-free use, high accuracy, fast response, automatic temperature compensation, and no reagents needed. This chlorine sensor is suitable for water plants, rural drinking water, stations, and secondary supply for reliable monitoring.\u003c\/div\u003e\n\u003cdiv class=\"detail_other_message flex flex-col no_margin_left detail_other_message_0\"\u003e\n\u003cdiv class=\"detail_other\"\u003e\n\u003cspan class=\"detail_title is-default\"\u003eModel\u003c\/span\u003e\u003cspan\u003e ：ACL-110 \u003c\/span\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"detail_other\"\u003e\n\u003cspan\u003e\u003c\/span\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"detail_other\"\u003e\n\u003cspan\u003e\u003c\/span\u003e\u003cbr\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"detail_other\"\u003e\n\u003cp\u003e\u003cspan\u003eFREE CHLORINE SENSOR, CHLORINE DIOXIDE SENSOR\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eThis sensor is different from traditional electrodes. It is manufactured with cutting-edge Swiss technology, using silicon nitride-coated photopolymer films and silicon crystal semiconductors as conductive elements. It has built-in chlorine and temperature probes.\u003c\/p\u003e\n\u003cp\u003eThrough MEMS technology, microelectronic components are injection-molded and encapsulated.\u003c\/p\u003e\n\u003cp\u003eAs the free chlorine or chlorine dioxide concentration in the water sample changes,the sensorgenerates\u003c\/p\u003e\n\u003cp\u003edifferent current intensities, which are processed by a regulator and signal amplifier, and converted into standard Modbus RS485 signals.\u003c\/p\u003e\n\u003cp\u003eThe sensor does not require the replacement of reagents during use, and is easy to maintain, ensuring the stability, reliability, and accuracy of the instrument's long-term operation. It can be used in water plants, rural drinking water, water stations, secondary water supply, and other fields.\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eFEATURES\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e●ACL-110 with \u003c\/span\u003eDigital RS485 interface（or ACL-111 with  Analog 0-5V output）\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e●\u003c\/span\u003eDirect insertion in the pipeline, with a pressure resistance of 10 bar\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e●\u003c\/span\u003eMeasurement values are not affected by flow rate and pressure\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e●\u003c\/span\u003eContinuous use on-site for 12 months without\u003cspan\u003e \u003c\/span\u003e\u003cspan\u003ecalibration and maintenance\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e●\u003c\/span\u003eHigh measurement accuracy, fast response time, and high repeatibility\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003e●\u003c\/span\u003eAutomatic temperature compensation\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eTECHNICAL PARAMETERS\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003eRange:0~5mg\/L\u003c\/p\u003e\n\u003cp\u003eResolution:0.01mg\/L\u003c\/p\u003e\n\u003cp\u003eResponse time; Less than 30s after polarization is completed\u003c\/p\u003e\n\u003cp\u003eAccuracy (@ 25°C pH7.2):\u003c\/p\u003e\n\u003cp\u003e0-2mg\/L:        ≤0.1mg\/L,   absolute error ±0.01mg\/L;\u003c\/p\u003e\n\u003cp\u003e0.1≤X≤2mg\/L: relative error ±5% or ±0.03mg\/L(Take the larger value)\u003c\/p\u003e\n\u003cp\u003e2-5mg\/L        :\u003cspan\u003e \u003c\/span\u003e\u003cspan\u003erelative error \u003c\/span\u003e±5% or ±0.25mg\/L(\u003cspan\u003eTake the larger value\u003c\/span\u003e)\u003c\/p\u003e\n\u003cp\u003epH range: 5-9, the membrane head will be damaged if it is below 5\u003c\/p\u003e\n\u003cp\u003eSample flow rate:12-30L\/H, in the flow chamber D20\u003c\/p\u003e\n\u003cp\u003eTemperature compensation: PT1000, built-in integrated automatic compensation\u003c\/p\u003e\n\u003cp\u003eStorage temperature: 0-40\u003cspan\u003e°C\u003c\/span\u003e\u003cspan\u003e \u003c\/span\u003e(no condensation)\u003c\/p\u003e\n\u003cp\u003eOutput interface: RS485(standard MODBUS protocol)\u003c\/p\u003e\n\u003cp\u003ePower supply voltage: 12VDC ±2V \u003c\/p\u003e\n\u003cp\u003ePower consumption: Below 0.5W\u003c\/p\u003e\n\u003cp\u003ePhysical dimensions: Diameter 32mm, length 171mm\u003c\/p\u003e\n\u003cp\u003eMaterial:PVC and Viton°O-ring seal\u003c\/p\u003e\n\u003cp\u003eConnection method:5-core waterproof aerospace connector\u003c\/p\u003e\n\u003cp\u003eMaximum pressure: 10bar\u003c\/p\u003e\n\u003cp\u003eThread size: NPT3\/4\"\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Awesentec","offers":[{"title":"Default Title","offer_id":45007151267976,"sku":null,"price":300.0,"currency_code":"CAD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0730\/2705\/9848\/files\/111_9c38ce46-152f-446b-b44e-fceb73e9aa61.jpg?v=1775676710","url":"https:\/\/awesentec.com\/products\/components-example-product-1","provider":"Awesentec","version":"1.0","type":"link"}