ACL-110 Digital Free Chlorine/Chlorine Dioxide Sensor

ACL-110 Digital Free Chlorine/Chlorine Dioxide Sensor

$300.00
Sale price  $300.00 Regular price 
Skip to product information
ACL-110 Digital Free Chlorine/Chlorine Dioxide Sensor

ACL-110 Digital Free Chlorine/Chlorine Dioxide Sensor

$300.00
Sale price  $300.00 Regular price 
This ACL-110  free chlorine/chlorine dioxide sensor uses advanced Swiss technology with silicon nitride-coated films and silicon semiconductors, plus built-in chlorine/temperature probes. MEMS-based microelectronics are injection-molded for durability.
It detects free chlorine/chlorine dioxide via varying currents (concentration-dependent), processed to standard Modbus RS485 signals.With features of 10 bar pressure resistance, flow/pressure immunity, 9 months of maintenance-free use, high accuracy, fast response, automatic temperature compensation, and no reagents needed. This chlorine sensor is suitable for water plants, rural drinking water, stations, and secondary supply for reliable monitoring.
Model :ACL-110 


FREE CHLORINE SENSOR, CHLORINE DIOXIDE SENSOR

This sensor is different from traditional electrodes. It is manufactured with cutting-edge Swiss technology, using silicon nitride-coated photopolymer films and silicon crystal semiconductors as conductive elements. It has built-in chlorine and temperature probes.

Through MEMS technology, microelectronic components are injection-molded and encapsulated.

As the free chlorine or chlorine dioxide concentration in the water sample changes,the sensorgenerates

different current intensities, which are processed by a regulator and signal amplifier, and converted into standard Modbus RS485 signals.

The sensor does not require the replacement of reagents during use, and is easy to maintain, ensuring the stability, reliability, and accuracy of the instrument's long-term operation. It can be used in water plants, rural drinking water, water stations, secondary water supply, and other fields.


FEATURES


●ACL-110 with Digital RS485 interface(or ACL-111 with  Analog 0-5V output)

Direct insertion in the pipeline, with a pressure resistance of 10 bar

Measurement values are not affected by flow rate and pressure

Continuous use on-site for 12 months without calibration and maintenance

High measurement accuracy, fast response time, and high repeatibility

Automatic temperature compensation


TECHNICAL PARAMETERS

Range:0~5mg/L

Resolution:0.01mg/L

Response time; Less than 30s after polarization is completed

Accuracy (@ 25°C pH7.2):

0-2mg/L:        ≤0.1mg/L,   absolute error ±0.01mg/L;

0.1≤X≤2mg/L: relative error ±5% or ±0.03mg/L(Take the larger value)

2-5mg/L        : relative error ±5% or ±0.25mg/L(Take the larger value)

pH range: 5-9, the membrane head will be damaged if it is below 5

Sample flow rate:12-30L/H, in the flow chamber D20

Temperature compensation: PT1000, built-in integrated automatic compensation

Storage temperature: 0-40°C (no condensation)

Output interface: RS485(standard MODBUS protocol)

Power supply voltage: 12VDC ±2V 

Power consumption: Below 0.5W

Physical dimensions: Diameter 32mm, length 171mm

Material:PVC and Viton°O-ring seal

Connection method:5-core waterproof aerospace connector

Maximum pressure: 10bar

Thread size: NPT3/4"

You may also like